The IGMC-111GP is a cost-effective solution for a conversion interface between 10/100/1000Base-T(X) and a 100/1000Base-X SFP socket. It allows the user to extend communication distance by super fast optical fibre. The IGMC-111GP supports MDI/MDIX auto detection, therefore crossover wires are not needed.
As well as this LFP (Link Fault Pass-through) is also supported. When one side of the link fails, the other side continues transmitting packets, and waiting for a response that never arrives from the disconnected side. Use the DIP-Switch to enable the LFP function, then IGMC-111GP will force the link to shut down as soon as noticed that the other link has failed, giving the application software a chance to react to the situation.
The IGMC-111GP has huge operating temperature range, from -40 ~ 75°C it can handle almost any operating environment. Furthermore it also accepts a wide voltage range from dual 12~48 VDC power inputs.
Specification | |
10/100/1000 Base-T(X) Port in RJ45 Auto MDI/MDIX | 1 |
100/1000Base-X SFP por | 1 |
Ethernet Standards |
IEEE 802.3i for 10Base-T |
Jumbo Frame | 9K Bytes (1G mode only) |
Power / Ready Indicator | Green: Power LED x 2 |
LFP Statue Indicator | Amber: (ON) LFP function fail / (OFF) LFP function disable |
100/1000Base-X SFP Port Indicator | Green: Port Link / Act |
10/100/1000Base-T(X) Port Duplex Mode Indicator | Green: (ON) Full-duplex mode / (OFF) Half-Duplex mode |
10/100/1000Base-T(X) RJ45 port Indicator |
Green: Link/Act
|
Fault Indicator | Amber: Indicate unexpected event occurred |
Relay | Relay output to carry capacity of 1A at 24 VDC |
Input Power | Dual 12~ 48 VDC voltage power inputs in 4-pin terminal block |
Power Consumption (Typ.) | 4 W |
Overload Current Protection | Yes |
Reverse Polarity Protection | Yes |
Enclosure | IP-30 Rated |
Dimensions (W x D x H) | 30 x 70 x 96 mm |
Weight | 291 g |
Storage Temperature | -40 to 85°C |
Operating Temperature | -40 to 75°C |
Operating Humidity | 5% to 95% Non-condensing |
EMI | FCC Part 15, CISPR (EN55022) class A |
EMS |
EN61000-4-2 (ESD) |
Shock | IEC60068-2-27 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
Safety | EN60950-1 |
Warranty | 5 years |
Unit 36, 41-49 Norcal Road,
Nunawading,
Victoria, 3131,
Australia
PH: +61 3 8736 0330